3 Maintenance
Attach a new waste toner bottle.
1Insert the mouth of the waste toner bottle onto the
waste toner discharge port of the main unit by slightly
lifting it.
2Set it onto the bottom surface and position it so that
it is stable.
After the following message appears, the device status
will return to the status before the waste bottle was
replaced.
Close the waste door.
When you have removed the waste toner bottle, the
LCD will display the following message.
Attach the cap to the waste toner bottle.
Attach the cap which you have removed in procedure
to the waste bottle containing waste toner.
Dispose of the waste bottle containing waste toner as
non-burnable garbage.
Note
◆ Attach the cap securely as it may come off.
When the Process cartridge approaches the end of its life, the
Process lamp flashes and the following message appears. It
is still possible to continue to produce plots in this condition,
but you must replace the cartridge soon.
Note
◆ Above message may not appear in certain cases.
If a new pocess cartridge is not installed soon, the Process
lamp goes out, Error lamp comes on and plotting becomes
impossible. The following error message appears on LCD.
Replacing the process cartridge
When the Process lamp flashes or goes out, follow the
procedures indicated below to replace the Process cartridge.
◆
Precautions during replacement
Warning
◆ Do not throw the process cartridge into fire.
Doing so may cause accident and fire.
Dispose of process cartridge as non-burnable
garbage.
SET
WAS T E BOT T L E
New bottle Bottle containing waste toner
WA I T A MOMENT
PR I NT READY
REPLACE PROCESS
SET
PROCESS CARTR I DGE