E
161 160
TM-T90
Specification
(STANDARD)
GS ^ r t m
[Name] Execute macro
[Format] ASCII GS ^ r t m
Hex 1D 5E r t m
Decimal 29 94 r t m
[Range] 0 r 255
0 t 255
m = 0, 1
[Description] Executes a macro.
r specifies the number of times to execute the macro.
t specifies the waiting time for executing the macro.
m specifies macro executing mode from the table below.
m Function
0
Executes the macro r times at the intervals specified by t × 100 ms.
1
After waiting for the time specified by t × 100 ms, the PAPER OUT LED
flashes to indicate that the FEED button must be pressed. After the button
is pressed, the macro is executed once. This operation is then repeated r
times.