(3) BACK ADJUST PRINT
When adjusting the media back adjustment
(when PH cleaning mode [DURING PRNT] is
selected), print the back adjust print.
Select the parameters to meet the respective
print mode.
<Parameter (selection input)>
Print mode Using MEDIA ADV PRINT
NORMAL1, NORMAL2 NORMAL1
QUALITY QUALITY
DENSITY DESITY
DRAFT DRAFT
FINE DRAFT FINE DRAFT
(4) BACK ADJUST VAL
Set the back adjust value of the media. Read-
ing the print result of back adjust print, enter
the back adjust value.
<Parameter (numeral input)>
+/2000 pulses (Unit : about 3.5 μm)
Note
- The back adjust value of the media is valid when the PH cleaning mode
[DURING PRNT] is set. ( P.3-34 [(26) PH CLEANING])
#BACK ADJ PRINT
>NORMAL1
XXXXXX : Media name
#BACK ADJUST VAL
#XXXXXX>+0000P